Hazardous Duty Synchronous Motors

These synchronous motors are available in UL Listed versions suitable for use in Class I, Division 1&2, Group D hazardous locations. They provide torque up to 1,500 oz-in (1059 N-cm) and are available in NEMA 42 and 66 frame sizes (110 mm and 170 mm).

Global
Limited availability outside North America

Features

  • Motor torque up to 1,500 oz-in (1059 N-cm)
  • 72 rpm at 60 Hz, 60 rpm at 50 Hz
  • 120 and 240 volt AC versions
  • UL Listed versions meet Class I, Division 1&2, Group D requirements
  • UL Listed versions have a conduit connection

Specifications

120 Volt, 60 Hz, Single Phase, 72 rpm

Phase Shifting
* Type Number Torque (min) # Load Inertia amps Wiring Diagram Resistor Capacitor (330VAC)
UL oz-in N-cm lb-in2 kg-cm Kit Number ohms watts Kit Number µF
X250 250 177 3 8.8 0.6 RC 201052-013 150 50 201053-010 6.5
X700 700 494 10 30 1.1 RC 201052-027 150 100 201053-032 12.5
X1100 1,100 777 9 26 3 RC 201052-025 100 160 201053-026 17.5
X1500 1,500 1,059 12 35 3 RC 201052-020 55 375 201053-014 30

240 Volt, 60 Hz, Single Phase, 72 rpm

Phase Shifting
* Type Number Torque (min) # Load Inertia amps Wiring
Diagram
Resistor Capacitor (660VAC)
UL oz-in N-cm lb-in2 kg-cm Kit Number ohms watts Kit Number µF
X252 250 177 3 8.8 0.4 RC 201052-015 500 50 201053-012 1.75
X1102 1,100 777 9 26 1.5 RC 201052-026 400 160 201053-028 4
X1502 1,500 1,059 12 35 1.5 RC 201052-018 250 200 201053-016 8

240 Volt, 60 Hz, Single Phase, 60 rpm

Phase Shifting
* Type Number Torque (min) # Load Inertia amps Wiring
Diagram
Resistor Capacitor (660VAC)
UL oz-in N-cm lb-in2 kg-cm Kit Number ohms watts Kit Number µF
X252 250 177 3 8.8 0.4 RC 201052-015 500 50 201053-012 1.75
X1102 1,100 777 9 26 1.5 RC 201052-026 400 160 201053-029 6
X1502 1,500 1,059 12 35 1.5 RC 201052-018 250 200 201053-019 9

# This is the maximum rigidly attached load inertia the motor will reliably start. If the load is attached to the motor with a coupling that has a 5º flex, the motor can start loads up to seven times listed.

Media & Downloads

Title Language Date Share URL
Explosion Proof Motor Brochure English Share URLview
Kollmorgen AC Synchronous Motor Selection Guide English Share URLview
Kollmorgen Full-line Catalog English Share URLview
PacSci Step Sync Selection Guide EN 2000 English Share URLview
Stepper and Synchronous Motors Catalog EN Rev C English Share URLview
X Series Hazardous Duty Synchronous Motor Selection Guide English Share URLview
Title File Language Date Share URL
Blue Guide English, German
Share URL https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=OJ%3AC%3A2022%3A247%3ATOC

These 3D models are intended to guide your design activities and may be used as reference information. Be sure to consult a Kollmorgen expert to ensure you have the most current and accurate information for critical aspects of design work.

Title File Language Date Share URL
Superior Synchronous Connection Diagrams EN English
Share URL /sites/default/files/public_downloads/Superior-Synchronous-Connection-Diagrams_en_US.pdf

Engineer the Exceptional

Learn how to engineer exceptional machines, robots and vehicles with the highest-performing, most reliable motors, drives, automation solutions and more.

Learn More